Integrations tag


M-REL-C4s: Module with four relay outputs

Module M-REL-C4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four relay outputs and four ground-detecting inputs. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update April 21, 2026, tags: Ampio CAN modules, REL family, DIN rail modules, Integrations, Input modules, Output modules, Relay outputs, Lights, Security, Roller shutters and blinds, Wall switch

M-OC-C8s: Module with eight OC outputs and an RGBW controller functionality

Module M-OC-C8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight OC outputs, four ground-detecting inputs and supports the functionality of an RGBW lighting controller.

Last update April 21, 2026, tags: CCT, Ampio CAN modules, OC family, Integrations, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating, Security, Wall switch

M-CON-KNX-s: KNX integration module MKNX-1s

Module M-CON-KNX-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module enables two-way communication between devices operating within the CAN and KNX bus.

Last update April 21, 2026, tags: Ampio CAN modules, CON family, DIN rail modules, Lights, Dimmer, KNX, Integrations

M-CON-ENOCN-p: EnOcean integration module EnOcean-1p

Module M-CON-ENOCN-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module is used for integration with devices that support the EnOcean 868Mhz wireless communication standard.

Last update April 21, 2026, tags: Ampio CAN modules, CON family, Junction box modules, EnOcean, Integrations

M-CON-DL-s: DALI bus integration module MDALI-1s, M-CON-DALI-s

There are two methods for connecting the power supply to the M-CON-DL-s module, depending on the number of controllers. A detailed diagram is provided at the end of this manual. Module M-CON-DL-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC.

Last update April 21, 2026, tags: CCT, Ampio CAN modules, CON family, Output modules, DIN rail modules, Lights, Dimmer, Dali, Integrations, LED lights, RGBW lights

M-ROOM-s: Comprehensive apartment administration module MultiRoom-1s Discontinued

Module M-ROOM-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 21, 2026, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-ROOM-s PRO: Comprehensive apartment administration module

Module M-ROOM-s PRO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 21, 2026, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, RS-485, Security

M-AV-AMP-s: Bus receiver module MAMP-1s

Module M-AV-AMP-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. Adding the module to the Ampio installation makes it possible to play music automatically when someone enters the house, or lower the volume after a certain hour.

Last update April 21, 2026, tags: Ampio CAN modules, AV family, Output modules, Integrations, DIN rail modules

Integration with Tedee lock

A guide for the integration of Gerda’s Tedee locks with the Ampio system.

Last update January 5, 2026, tags: SERV family, Integrations, Configuration, IP, Mobile app, Access control

M-SERV-NANO PRO: Remote management module in the form of an industrial computer

The diagrams and visualisations in the M-SERV-NANO PRO module documentation are for illustrative purposes only. Each project is considered individually and tailored to the customer’s requirements. The M-SERV-NANO PRO module is part of the Ampio system. The module is powered from the server’s USB port and a CAN bus cable in the range of 11-16V DC.

Last update December 15, 2025, tags: Ampio CAN modules, SERV family, Integrations, Ampio Cloud, IP, Mobile app, Node-RED, Central heating