M-DOT-9: 9-fields touch panel module

Module M-DOT-9 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has nine sensor fields and a 1-Wire interface. Sensor fields The touch panel sensor fields are capacitive buttons located behind the glass pane, which is the front of the module.

Last update March 7, 2023, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Input modules, Wall switch, Touch panels, Personalisation

M-DOT-R14: 14-fields touch panel module with an RFID reader

Module M-DOT-R14 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has fourteen sensor fields, an RFID card reader and a 1-Wire interface.

Last update February 10, 2023, tags: Ampio CAN modules, DOT family, Input modules, Wall switch, Touch panels, Personalisation, Security, Access control, RFID

M-IN-16s: Module with sixteen bi-state inputs

Module M-IN-16s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has sixteen alarm inputs. Alarm inputs The module has bi-state inputs that go into an active state when they are shorted to ground, allowing for the connection of any devices with potential-free contact outputs or optocoupler outputs.

Last update January 17, 2023, tags: Ampio CAN modules, IN family, DIN rail modules, Wall switch, Sensors, Input modules

M-OUT-4p: Module with four voltage analogue outputs and inputs

Module M-OUT-4p is a component of the Ampio system. Required voltage to power the module is 12 — 16V DC. The module is controlled via CAN bus. The module has four voltage analogue outputs, four analogue inputs and a 1-Wire interface.

Last update January 17, 2023, tags: Ampio CAN modules, OUT family, Output modules, Junction box modules, Input modules, Integrations, Dallas 18B20

M-SERV-s: Remote system management and IP integrations module MSERV-4s

Module M-SERV-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - and it enables IP integrations.

Last update January 12, 2023, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, OWA lighting, LED lights, Open-collector drivers, Central heating, SATEL, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, RS-232, Security

M-ROOM-s: Comprehensive apartment administration module MultiRoom-1s

Module M-ROOM-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update January 12, 2023, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-LED-s: Ampio lighting bus controller

Module M-LED-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. OWA lighting bus The OWA lighting bus (One Wire Ampio) is a solution dedicated to controlling LED lighting.

Last update January 12, 2023, tags: Ampio CAN modules, LED family, DIN rail modules, Output modules, Dimmer, LED lights, Lights, OWA lighting

M-LED-p: Ampio lighting bus controller

Module M-LED-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. It also has four ground-detecting inputs and a 1-Wire interface.

Last update January 12, 2023, tags: Ampio CAN modules, LED family, Junction box modules, Wall switch, Sensors, Input modules, Output modules, Dallas 18B20, Dimmer, LED lights, Lights, OWA lighting, Central heating

M-OC-C8s: Module with eight OC outputs and an RGBW controller functionality

Module M-OC-C8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight OC outputs, four ground-detecting inputs and supports the functionality of an RGBW lighting controller.

Last update December 5, 2022, tags: Ampio CAN modules, OC family, Integrations, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating, Security, Wall switch

M-CON-ZWAVE-s: Z-Wave integration module MZWAVE-1s

Module M-CON-ZWAVE-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for integration with a number of devices that support the Z-Wave wireless communication protocol.

Last update October 24, 2022, tags: Ampio CAN modules, CON family, Sensors, Wall switch, Central heating, DIN rail modules, Integrations