M-REL-10s: Module with ten relay outputs

Module M-REL-10s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has ten relay outputs, ten ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update April 21, 2026, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-IN-16s: Module with sixteen bi-state inputs

Module M-IN-16s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has sixteen alarm inputs. Alarm inputs The module has bi-state inputs that go into an active state when they are shorted to ground, allowing for the connection of any devices with potential-free contact outputs or optocoupler outputs.

Last update April 21, 2026, tags: Ampio CAN modules, IN family, DIN rail modules, Wall switch, Input modules

M-OUT-4p: Module with four voltage analogue outputs and inputs

Module M-OUT-4p is a component of the Ampio system. Required voltage to power the module is 12 — 16V DC. The module is controlled via CAN bus. The module has four voltage analogue outputs, four analogue inputs and a 1-Wire interface.

Last update April 21, 2026, tags: Ampio CAN modules, OUT family, Output modules, Junction box modules, Input modules, Integrations, Dallas 18B20

M-OUT-4s: Module with four voltage analogue outputs

Module M-OUT-4s is a component of the Ampio system. Required voltage to power the module is 12 — 16V DC. The module is controlled via CAN bus. The module has four voltage analogue outputs. Voltage analogue outputs Voltage analogue outputs allow for integration with devices that have voltage control inputs compatible with the 0 — 10V DC, 1 — 10V DC, 0 — 5V DC standard, e.

Last update April 21, 2026, tags: Ampio CAN modules, OUT family, Output modules, DIN rail modules, Integrations

M-REL-C4s: Module with four relay outputs

Module M-REL-C4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four relay outputs and four ground-detecting inputs. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update April 21, 2026, tags: Ampio CAN modules, REL family, DIN rail modules, Integrations, Input modules, Output modules, Relay outputs, Lights, Security, Roller shutters and blinds, Wall switch

M-OC-4s: Module with four OC outputs and an RGBW controller functionality MRGBWOC-4s

Module M-OC-4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four OC outputs and supports the functionality of an RGBW lighting controller.

Last update April 21, 2026, tags: CCT, Ampio CAN modules, OC family, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating

M-INOC-4p: Module with four bi-state inputs, four OC outputs and an RGBW controller functionality MRGBWOC-4p

Module M-INOC-4p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four ground-detecting inputs, four OC outputs, and a 1-Wire interface. It also supports the functionality of the RGBW lighting controller.

Last update April 21, 2026, tags: CCT, Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Junction box modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating

M-IN-AC4s: Module with four AC inputs

Module M-IN-AC4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four AC inputs. AC inputs The module has inputs that go into an active state when they are connected to an alternating voltage in the range of 110 — 250V AC.

Last update April 21, 2026, tags: Ampio CAN modules, IN family, DIN rail modules, Input modules

M-IN-11p: Module with eleven bi-state inputs Discontinued

Module M-IN-11p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eleven voltage-detecting inputs, eleven LED outputs, and a 1-Wire interface.

Last update April 21, 2026, tags: Ampio CAN modules, IN family, Junction box modules, Wall switch, Sensors, Input modules, Dallas 18B20

M-REL-8s: Module with eight relay outputs MROL-8s Discontinued

Module M-REL-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight relay outputs, eight ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update April 21, 2026, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch