Ampio CAN modules tag


M-DOT-M18: 18-fields touch panel module with a display

Module M-DOT-M18 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eighteen sensor fields, a display supporting the functionality of swipeable screens, and a 1-Wire interface.

Last update February 18, 2025, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Input modules, Display, Data visualisation, Wall switch, Touch panels, Personalisation, Security, Access control

M-DOT-18: 18-fields touch panel module

Module M-DOT-18 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eighteen sensor fields and a 1-Wire interface. Sensor fields The touch panel sensor fields are capacitive buttons located behind the glass pane, which is the front of the module.

Last update February 18, 2025, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Input modules, Wall switch, Touch panels, Personalisation

M-IN-AD8s: Module with eight analogue inputs

Module M-IN-AD8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight analogue inputs. Analogue inputs The module has inputs that allow for voltage measurement in the range of 0 — 10V DC.

Last update January 24, 2025, tags: Ampio CAN modules, IN family, DIN rail modules, Input modules, Analogue control

M-SERV-s: Remote system management and IP integrations module MSERV-4s

Module M-SERV-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - and it enables IP integrations.

Last update October 29, 2024, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, OWA lighting, LED lights, Open-collector drivers, Central heating, SATEL, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, RS-232, Security

M-SERV-MINI-s: Remote system management and IP integrations module

Module M-SERV-MINI-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-MINI-s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - and enables IP integrations.

Last update October 29, 2024, tags: Ampio CAN modules, SERV family, Output modules, DIN rail modules, Integrations, Ampio Cloud, IP, Mobile app, Node-RED, Open-collector drivers, Central heating

M-CON-KEY-p: Module for integrating access control systems

Module M-CON-KEY-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four OC binary outputs. Typical application Integration of access control modules via the Wiegand bus.

Last update October 9, 2024, tags: Ampio CAN modules, CON family, Integrations, Output modules, Junction box modules

M-LED-s: Ampio lighting bus controller

Module M-LED-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. OWA lighting bus The OWA lighting bus (One Wire Ampio) is a solution dedicated to controlling LED lighting.

Last update September 11, 2024, tags: Ampio CAN modules, LED family, DIN rail modules, Output modules, Dimmer, LED lights, Lights, OWA lighting

M-LED-p: Ampio lighting bus controller

Module M-LED-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. It also has four ground-detecting inputs and a 1-Wire interface.

Last update September 11, 2024, tags: Ampio CAN modules, LED family, Junction box modules, Wall switch, Sensors, Input modules, Output modules, Dallas 18B20, Dimmer, LED lights, Lights, OWA lighting, Central heating

M-REL-2s: Module with two relay outputs MROL-2s

Module M-REL-2s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two relay outputs and supports the functionality of a controller for the roller shutters and blinds’drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, DIN rail modules, Output modules, Relay outputs, Lights, Roller shutters and blinds

M-REL-2p: Module with two relay outputs MROL-2p

Module M-REL-2p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two relay outputs, two ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch