Input modules tag


M-SERV-s: Remote system management and IP integrations module MSERV-4s

Module M-SERV-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - and it enables IP integrations.

Last update October 29, 2024, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, OWA lighting, LED lights, Open-collector drivers, Central heating, SATEL, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, RS-232, Security

M-SERV-3s: Remote system management and IP integrations module Discontinued

Module M-SERV-3s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-3s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - plus, it enables IP integrations.

Last update October 29, 2024, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, LoRa

M-INOC-4p: Module with four bi-state inputs, four OC outputs and an RGBW controller functionality MRGBWOC-4p

Module M-INOC-4p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four ground-detecting inputs, four OC outputs, and a 1-Wire interface. It also supports the functionality of the RGBW lighting controller.

Last update October 14, 2024, tags: Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Junction box modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating

M-INOC-8s: Module with eight bi-state inputs and eight OC outputs

Module M-INOC-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight ground-detecting inputs, eight OC outputs, and a 1-Wire interface.

Last update October 14, 2024, tags: Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, DIN rail modules, Lights, LED lights, Open-collector drivers, Central heating

M-LED-p: Ampio lighting bus controller

Module M-LED-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. It also has four ground-detecting inputs and a 1-Wire interface.

Last update September 11, 2024, tags: Ampio CAN modules, LED family, Junction box modules, Wall switch, Sensors, Input modules, Output modules, Dallas 18B20, Dimmer, LED lights, Lights, OWA lighting, Central heating

WL-REL-2p: Wireless module with two relay outputs RF PR-2p

Module WL-REL-2p is a component of the Ampio system. Required voltage to power the module is 110 — 250V AC. The module is controlled via the Ampio LoRa wireless interface. The module has two relay outputs and two AC inputs.

Last update July 29, 2024, tags: Ampio LoRa wireless modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Lights, Wall switch, Wireless, LoRa

M-REL-2p: Module with two relay outputs MROL-2p

Module M-REL-2p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two relay outputs, two ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-C10s: Module with ten relay outputs

Module M-REL-C10s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has ten relay outputs and supports the functionality of a controller for the roller shutters and blinds' drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-10s: Module with ten relay outputs

Module M-REL-10s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has ten relay outputs, ten ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-C4s: Module with four relay outputs

Module M-REL-C4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four relay outputs and four ground-detecting inputs. It also supports the functionality of a controller for the roller shutters and blinds' drives.