Sensors tag


M-IN-11p: Module with eleven bi-state inputs Discontinued

Module M-IN-11p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eleven voltage-detecting inputs, eleven LED outputs, and a 1-Wire interface.

Last update April 21, 2026, tags: Ampio CAN modules, IN family, Junction box modules, Wall switch, Sensors, Input modules, Dallas 18B20

M-INOC-8s: Module with eight bi-state inputs and eight OC outputs

Module M-INOC-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight ground-detecting inputs, eight OC outputs, and a 1-Wire interface.

Last update April 21, 2026, tags: CCT, Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, DIN rail modules, Lights, LED lights, Open-collector drivers, Central heating

M-IN-8s: Module with eight bi-state inputs

Module M-IN-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight ground detecting inputs, eight LED outputs and a 1-Wire interface.

Last update April 21, 2026, tags: Ampio CAN modules, IN family, DIN rail modules, Wall switch, Sensors, Input modules

M-ROOM-s: Comprehensive apartment administration module MultiRoom-1s Discontinued

Module M-ROOM-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 21, 2026, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-ROOM-s PRO: Comprehensive apartment administration module

Module M-ROOM-s PRO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 21, 2026, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, RS-485, Security

M-LED-p: Ampio lighting bus controller

Module M-LED-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. It also has four ground-detecting inputs and a 1-Wire interface.

Last update April 21, 2026, tags: Ampio CAN modules, LED family, Junction box modules, Wall switch, Sensors, Input modules, Output modules, Dallas 18B20, Dimmer, LED lights, Lights, OWA lighting, Central heating

M-DOT-R PRO: Panel module with built-in RFID reader

Module M-DOT-R PRO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-DOT-R PRO module is available for sale by special order. The minimum order for the R PRO series is 10 items.

Last update February 19, 2026, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Security, Access control, RFID

M-SENS: Ambient conditions measuring module

Module M-SENS is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for the measurement of ambient conditions in closed spaces. The device is also equipped with an IR receiver, which makes it possible to receive commands from remote controls based on the NEC protocol.

Last update June 17, 2025, tags: Ampio CAN modules, SENS family, Input modules, Sensors, Personalisation

M-SENS-LITE: Ambient conditions measuring module MSENS-1

Module M-SENS-LITE is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for the measurement of ambient conditions in closed spaces. Measurement of ambient conditions The module facilitates measuring a number of parameters for the environmental conditions present in closed spaces.

Last update June 17, 2025, tags: Ampio CAN modules, SENS family, Input modules, Sensors, Personalisation

M-IN-2p: Module with two bi-state inputs

Module M-IN-2p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two ground detecting inputs, a 1-Wire interface and a brightness sensor.

Last update November 2, 2023, tags: Ampio CAN modules, IN family, Junction box modules, Wall switch, Sensors, Input modules, Dallas 18B20