M-REL-10s: Module with ten relay outputs

Module M-REL-10s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has ten relay outputs, ten ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update March 16, 2022, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

WL-REL-ROL1p: Wireless roller blinds controller module RF ROL-2p

Module WL-REL-ROL1p is a component of the Ampio system. Required voltage to power the module is 110 — 250V AC. The module is controlled via the Ampio LoRa wireless interface. The module has two AC inputs and two relay outputs in the roller shutter and blinds' drive controller mode.

Last update February 23, 2022, tags: Ampio LoRa wireless modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Roller shutters and blinds, Wireless, Wall switch, LoRa

WL-OC-RGBW1p: Wireless RGBW lighting controller RF RGBW-1p

Module WL-OC-RGBW1p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via the Ampio LoRa wireless interface. The module has four OC outputs operating in an RGBW lighting controller mode.

Last update February 23, 2022, tags: Ampio LoRa wireless modules, OC family, Junction box modules, Output modules, Lights, LED lights, RGBW lights, Wireless, LoRa

WL-REL-2p: Wireless module with two relay outputs RF PR-2p

Module WL-REL-2p is a component of the Ampio system. Required voltage to power the module is 110 — 250V AC. The module is controlled via the Ampio LoRa wireless interface. The module has two relay outputs and two AC inputs.

Last update February 23, 2022, tags: Ampio LoRa wireless modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Lights, Wall switch, Wireless, LoRa

M-DIM-1s: Single output dimmer module Discontinued

Module M-DIM-1s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has one dimmable output. Dimmable outputs With the use of the module, it is possible to control the light intensity of incandescent bulbs, halogens, dimmable LED bulbs and dimmable CFL fluorescent lamps.

Last update February 23, 2022, tags: Ampio CAN modules, DIM family, Output modules, DIN rail modules, Lights, Dimmer

M-REL-2s: Module with two relay outputs MROL-2s

Module M-REL-2s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two relay outputs and supports the functionality of a controller for the roller shutters and blinds’drives.

Last update February 23, 2022, tags: Ampio CAN modules, REL family, DIN rail modules, Output modules, Relay outputs, Lights, Roller shutters and blinds

M-REL-C4s: Module with four relay outputs

Module M-REL-C4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four relay outputs and four ground-detecting inputs. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update February 23, 2022, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-8s: Module with eight relay outputs MROL-8s Discontinued

Module M-REL-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight relay outputs, eight ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update February 23, 2022, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-CON-IR: IR integration module MIR

Module M-CON-IR is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module is used for IR integration. With the use of the module, it is possible to receive commands from remote controls based on the NEC protocol, and to send previously saved commands to external devices.

Last update February 23, 2022, tags: Ampio CAN modules, CON family, Output modules, Integrations, Personalisation, Air conditioning

M-DIM-2s: Dimmer module with two outputs

Module M-DIM-2s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two dimmable outputs. In the standard version of the module, the maximum power of the receiver connected to a single output is 150W.

Last update February 23, 2022, tags: Ampio CAN modules, DIM family, Output modules, DIN rail modules, Lights, Dimmer