Output modules tag


M-DIM-2s: Dimmer module with two outputs

Module M-DIM-2s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two dimmable outputs. In the standard version of the module, the maximum power of the receiver connected to a single output is 150W.

Last update April 21, 2026, tags: Ampio CAN modules, DIM family, Output modules, DIN rail modules, Lights, Dimmer

M-CON-DL-s: DALI bus integration module MDALI-1s, M-CON-DALI-s

There are two methods for connecting the power supply to the M-CON-DL-s module, depending on the number of controllers. A detailed diagram is provided at the end of this manual. Module M-CON-DL-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC.

Last update April 21, 2026, tags: CCT, Ampio CAN modules, CON family, Output modules, DIN rail modules, Lights, Dimmer, Dali, Integrations, LED lights, RGBW lights

M-ROOM-s: Comprehensive apartment administration module MultiRoom-1s Discontinued

Module M-ROOM-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 21, 2026, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-ROOM-s PRO: Comprehensive apartment administration module

Module M-ROOM-s PRO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 21, 2026, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, RS-485, Security

M-AV-AMP-s: Bus receiver module MAMP-1s

Module M-AV-AMP-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. Adding the module to the Ampio installation makes it possible to play music automatically when someone enters the house, or lower the volume after a certain hour.

Last update April 21, 2026, tags: Ampio CAN modules, AV family, Output modules, Integrations, DIN rail modules

M-AV-MP3-s: Audio file player module MP3-PLAYER Discontinued

Module M-AV-MP3-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows you to play audio files from an installed microSD card. It has an audio output that can be connected to the M-AV-MP3-s bus receiver module or other power amplifier.

Last update April 21, 2026, tags: Ampio CAN modules, AV family, Output modules, DIN rail modules

M-LED-s: Ampio lighting bus controller

Module M-LED-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. OWA lighting bus The OWA lighting bus (One Wire Ampio) is a solution dedicated to controlling LED lighting.

Last update April 21, 2026, tags: Ampio CAN modules, LED family, DIN rail modules, Output modules, Dimmer, LED lights, Lights, OWA lighting

M-LED-p: Ampio lighting bus controller

Module M-LED-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. It also has four ground-detecting inputs and a 1-Wire interface.

Last update April 21, 2026, tags: Ampio CAN modules, LED family, Junction box modules, Wall switch, Sensors, Input modules, Output modules, Dallas 18B20, Dimmer, LED lights, Lights, OWA lighting, Central heating

WL-REL-2p: Wireless module with two relay outputs RF PR-2p

Module WL-REL-2p is a component of the Ampio system. Required voltage to power the module is 110 — 250V AC. The module is controlled via the Ampio LoRa wireless interface. The module has two relay outputs and two AC inputs.

Last update August 22, 2025, tags: Ampio LoRa wireless modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Lights, Wall switch, Wireless, LoRa

WL-REL-ROL1p: Wireless roller blinds controller module RF ROL-2p

Module WL-REL-ROL1p is a component of the Ampio system. Required voltage to power the module is 110 — 250V AC. The module is controlled via the Ampio LoRa wireless interface. The module has two AC inputs and two relay outputs in the roller shutter and blinds' drive controller mode.

Last update January 7, 2025, tags: Ampio LoRa wireless modules, REL family, Junction box modules, Input modules, Output modules, Relay outputs, Roller shutters and blinds, Wireless, Wall switch, LoRa