Input modules tag


M-REL-C4s: Module with four relay outputs

Module M-REL-C4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four relay outputs and four ground-detecting inputs. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-8s: Module with eight relay outputs MROL-8s Discontinued

Module M-REL-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight relay outputs, eight ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update July 29, 2024, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-ROOM-s: Comprehensive apartment administration module MultiRoom-1s Discontinued

Module M-ROOM-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update July 29, 2024, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-ROOM-s PRO: Comprehensive apartment administration module

Module M-ROOM-s PRO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update July 29, 2024, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-SENS: Ambient conditions measuring module

Module M-SENS is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for the measurement of ambient conditions in closed spaces. The device is also equipped with an IR receiver, which makes it possible to receive commands from remote controls based on the NEC protocol.

Last update May 22, 2024, tags: Ampio CAN modules, SENS family, Input modules, Sensors, Personalisation

M-OUT-4p: Module with four voltage analogue outputs and inputs

Module M-OUT-4p is a component of the Ampio system. Required voltage to power the module is 12 — 16V DC. The module is controlled via CAN bus. The module has four voltage analogue outputs, four analogue inputs and a 1-Wire interface.

Last update April 15, 2024, tags: Ampio CAN modules, OUT family, Output modules, Junction box modules, Input modules, Integrations, Dallas 18B20

M-IN-11p: Module with eleven bi-state inputs

Module M-IN-11p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eleven voltage-detecting inputs, eleven LED outputs, and a 1-Wire interface.

Last update April 15, 2024, tags: Ampio CAN modules, IN family, Junction box modules, Wall switch, Sensors, Input modules, Dallas 18B20

M-IN-8s: Module with eight bi-state inputs

Module M-IN-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight ground detecting inputs, eight LED outputs and a 1-Wire interface.

Last update April 15, 2024, tags: Ampio CAN modules, IN family, DIN rail modules, Wall switch, Sensors, Input modules

M-DOT-15: 15-fields touch panel module with display Discontinued

Module M-DOT-15 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has fifteen sensor fields, a display and a 1-Wire interface. Sensor fields The touch panel sensor fields are capacitive buttons located behind the glass pane, which is the front of the module.

Last update April 15, 2024, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Display, Input modules, Wall switch, Touch panels, Personalisation

M-DOT-R14: 14-fields touch panel module with an RFID reader

Module M-DOT-R14 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has fourteen sensor fields, an RFID card reader and a 1-Wire interface.

Last update April 15, 2024, tags: Ampio CAN modules, DOT family, Input modules, Wall switch, Touch panels, Personalisation, Security, Access control, RFID