Output modules tag


M-CON-KEY-p: Module for integrating access control systems

Module M-CON-KEY-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four OC binary outputs. Typical application Integration of access control modules via the Wiegand bus; Integration of access control modules via RS-485 bus; Control of resistive loads supplied with voltages up to 24V DC, e.

Last update May 20, 2024, tags: Ampio CAN modules, CON family, Integrations, Sensors, Dallas 18B20, Output modules, Junction box modules

M-ROOM-s PRO: Comprehensive apartment administration module

Module M-ROOM-s PRO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 30, 2024, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-SERV-s: Remote system management and IP integrations module MSERV-4s

Module M-SERV-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - and it enables IP integrations.

Last update April 24, 2024, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, OWA lighting, LED lights, Open-collector drivers, Central heating, SATEL, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, RS-232, Security

M-OC-32s: Module with thirty-two bi-state OC outputs

Module M-OC-32s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has thirty-two two-state OC outputs. Bi-state OC outputs The module has open-collector outputs allowing for switching of resistive loads supplied with voltage up to 40V DC.

Last update April 15, 2024, tags: Ampio CAN modules, OC family, Output modules, DIN rail modules, Lights, LED lights, Open-collector drivers, Central heating

M-OUT-4p: Module with four voltage analogue outputs and inputs

Module M-OUT-4p is a component of the Ampio system. Required voltage to power the module is 12 — 16V DC. The module is controlled via CAN bus. The module has four voltage analogue outputs, four analogue inputs and a 1-Wire interface.

Last update April 15, 2024, tags: Ampio CAN modules, OUT family, Output modules, Junction box modules, Input modules, Integrations, Dallas 18B20

M-INOC-4p: Module with four bi-state inputs, four OC outputs and an RGBW controller functionality MRGBWOC-4p

Module M-INOC-4p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four ground-detecting inputs, four OC outputs, and a 1-Wire interface. It also supports the functionality of the RGBW lighting controller.

Last update April 15, 2024, tags: Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Junction box modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating

M-ROOM-s: Comprehensive apartment administration module MultiRoom-1s Discontinued

Module M-ROOM-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module can provide many of the functionalities envisioned by the Ampio building automation system’s architecture.

Last update April 15, 2024, tags: Ampio CAN modules, ROOM family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, LED lights, Open-collector drivers, Central heating, SATEL, Hotel, Roller shutters and blinds, RS-232, Security

M-LED-p: Ampio lighting bus controller

Module M-LED-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. It also has four ground-detecting inputs and a 1-Wire interface.

Last update April 15, 2024, tags: Ampio CAN modules, LED family, Junction box modules, Wall switch, Sensors, Input modules, Output modules, Dallas 18B20, Dimmer, LED lights, Lights, OWA lighting, Central heating

M-CON-IR: IR integration module MIR

Module M-CON-IR is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module is used for IR integration. With the use of the module, it is possible to receive commands from remote controls based on the NEC protocol, and to send previously saved commands to external devices.

Last update March 21, 2024, tags: Ampio CAN modules, CON family, Output modules, Integrations, Personalisation, Air conditioning

M-AV-AMP-s: Bus receiver module MAMP-1s

Module M-AV-AMP-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. Adding the module to the Ampio installation makes it possible to play music automatically when someone enters the house, or lower the volume after a certain hour.

Last update March 21, 2024, tags: Ampio CAN modules, AV family, Output modules, Integrations, DIN rail modules